Precision tools instrument

Buy Megger TTR310

SKU: 220
Brand:
Return: 30 days

$5.400

Megger TTR310 Transformer Turns Ratio Tester Used Item is in good cosmetic and high quality working condition.

or

Megger TTR310 Three-Phase Transformer Turns Ratio Test Set

The Megger TTR310 is a three phase transformer turns ratio (TTR) tester from Megger  TTR310 series built to measure the turns ratio of power, instrument, and distribution transformers in the substation or on the factory floor. It tests all three phases in one setup which saves a great deal of time compared with older single phase testers when working on complex transformers with multiple tap changers and bushing CTs. It is a stand alone instrument that can also be run from a PC and it is rugged enough for harsh field conditions.

Key Features

  • Three phase testing: tests all three phases without reconnecting the leads and stores test setups so repeat tests are quick
  • Wide ratio range and high accuracy: measures ratios up to 45,000:1 with accuracy of 0.1%
  • Ratio, phase deviation, and excitation current: measures all three in a single test
  • Phase deviation measurement: compares the primary and secondary phase relationship which helps reveal partially shorted turns and core faults and verifies phase errors in PTs and CTs
  • Pass/fail limits: applied to each individual ratio
  • Suited to difficult transformers: handles multiple tap changers and bushing current transformers efficiently
  • Transformer vector diagrams: supports a range of connections with optional vector voltage diagram sets for ANSI, IEC, and AS standards
  • Stand-alone or remote operation: use the instrument on its own or control it from a computer with the remote control software
  • Field upgradeable: upgrades can be made without affecting calibration
  • Cold-weather leads: specially designed for flexibility in low temperatures
  • Rugged and robust: designed for use in demanding environments

Typical Applications

  • Commissioning and acceptance testing of new transformers
  • Routine maintenance and diagnostic testing in substations
  • Verifying tap changer operation and ratios across all taps
  • Testing bushing CTs, current transformers, and potential transformers
  • Troubleshooting after faults, transport, or suspected winding damage
  • Quality control in transformer manufacturing and repair

Why Choose It

A turns ratio that drifts from nameplate values can point to shorted turns damaged insulation or other developing faults. The Megger TTR310 makes it fast and repeatable to check even on complex three phase units and gives clear documented results before a transformer is put into service or returned to it.

Megger TTR310 Buy Megger TTR310

$5.400